Sheave Test

Material
ACFR 160 mm2 (diameter = 18.2 mm)
with hard-drawn aluminum
Test Conditions
  • Sheave :Φ450(D/d=24.7)
  • Angle :60°
  • Tension :20 % UTS
  • Passing :20 times (shuttled)
Japanese Pulley Diameter
  • Φ1000
  • Φ600
  • Φ450
  • Φ300
  • Φ200

Check the conductor parts after the sheave test

The conductor and core have no deformation or nicking

Aluminum outermost layer

Inside of aluminum inner layer

Outside of aluminum inner layer

CFCC